Problem Statement: How can I get the workspace object count using Excel VBA automation? Explain with an example.
Solution: Please refer to attached sample Excel VBA automation file that you can open it with MS Excel version 2007 or later. For detail information please download it and look into the VBA code. Keywords: VB, VBA, Excel automation References: None
Problem Statement: Event Scheduler Demonstration Model
Solution: This event scheduler demo complements the example seen in solution 110095 The demo covers the following features: 1. Step up/down variable values, using temperature variable type as example Sequence UpFeed2TempBy10 step up stream Feed2 temperature by 10F Sequence DpwnFeed2TempBy15 step down stream Feed2 tem...
Problem Statement: What is the best way to model the CO2 Capture Process by TEA using Aspen Plus?
Solution: In 2006.5, new Amines property packages for MEA and MDEA with H2S and CO2 were developed and delivered as application examples. These models are being improved, updated, and extended to other amines and solvents. They are posted on the support web site as soon as they are reviewed and ready for public use. Th...
Problem Statement: What is the best way to model the CO2 Capture Process by DEPG using Aspen Plus?
Solution: In 2006.5, new Amines property packages for MEA and MDEA with H2S and CO2 were developed and delivered as application examples. These models are being improved, updated, and extended to other amines and solvents. They are posted on the support web site as soon as they are reviewed and ready for public use. Th...
Problem Statement: What is the best way to model the CO2 Capture Process by NH3 using Aspen Plus?
Solution: In 2006.5, new Amines property packages for MEA and MDEA with H2S and CO2 were developed and delivered as application examples. These models are being improved, updated, and extended to other amines and solvents. They are posted on the support web site as soon as they are reviewed and ready for public use. Th...
Problem Statement: What is the best way to model the CO2 Capture Process by DGA using Aspen Plus?
Solution: In 2006.5, new Amines property packages for MEA and MDEA with H2S and CO2 were developed and delivered as application examples. These models are being improved, updated, and extended to other amines and solvents. They are posted on the support web site as soon as they are reviewed and ready for public use. Th...
Problem Statement: What is the best way to model the CO2 Capture Process by Methanol (MeOH) using Aspen Plus?
Solution: In 2006.5, new Amines property packages for MEA and MDEA with H2S and CO2 were developed and delivered as application examples. These models are being improved, updated, and extended to other amines and solvents. They are posted on the support web site as soon as they are reviewed and ready for public use. Th...
Problem Statement: What is the best way to model the CO2 Capture Process by DEA using Aspen Plus?
Solution: In 2006.5, new Amines property packages for MEA and MDEA with H2S and CO2 were developed and delivered as application examples. These models are being improved, updated, and extended to other amines and solvents. They are posted on the support web site as soon as they are reviewed and ready for public use. Th...
Problem Statement: Is it possible to model a urea synthesis loop?
Solution: AspenTech has developed a data package for this type of system. It has been included with the general Aspen Plus V7.1 release in the Favorites\Applications directory. The package is our proprietary work. Consulting may be needed for technology transfer and further model development and validation. Urea Data P...
Problem Statement: Is it possible to model a cogeneration process?
Solution: Attached is an example of this process. This example will run in Aspen Plus 2006.5 and higher. Introduction This model simulates an Integrated Cogeneration process. It includes the following features: ? A set of conventional chemical species for this process. ? Typical process areas including:...
Problem Statement: What is the best way to model the CO2 Capture Process by AMP using Aspen Plus?
Solution: In 2006.5, new Amines property packages for MEA and MDEA with H2S and CO2 were developed and delivered as application examples. These models are being improved, updated, and extended to other amines and solvents. They are posted on the support web site as soon as they are reviewed and ready for public use. Th...
Problem Statement: How do I trap the Planning Board Activity Split type? We have had an issue with the ?Split By Controls? not working correctly after forcing a correction for one of the other split types.
Solution: The macros $PBBEF (before) and $PBAFT (after) can be used to trap user initiated planning board activities. These sets should have codes MOVE, CREATE, DUPLICATE, SPLIT, DELETE, COMBINE, EDIT corresponding to the various actions the user can initiate via the planning board interface. If no "trapping" is desi...
Problem Statement: You have a requirement to convert SCOLOR names to HEX values. Does AspenTech have a list of HEX values that can be cross referenced back to the original mimi colors? You have a need to use some of the new fx in graphs and dialogs, but these are not compatible with color names - such as "chocolate" - ...
Solution: By using the attached spreadsheet, you can convert HEX to SCOLOR and vice versa. Keywords: None References: None
Problem Statement: After installing new license file, getting error "Not licensed for M Commands".
Solution: In order to run an M command in SCM, your license file must contain the SLM_mimischd feature. Keywords: None References: None
Problem Statement: You recently upgraded your Excel version. Afterwards, any attempt to export data to excel generates an error.
Solution: You must change your location for Excel in the FMTFDEV table. This must reflect your new location for Excel. Keywords: FMTDATA Excel 2003 References: None
Problem Statement: You have just installed a new license file which contains the SLM_mimischd feature, however, you are still unable to run any M command.
Solution: Check the license file for which bucket said feature exists in. If not in the default bucket, you must add this through the SLM Configuration Wizard. Thus, we need to set up the SLM Configuration wizard to read said bucket as well as the default. Here is a screen shot example of where you need to set it. Keyw...
Problem Statement: After upgrading Aspen SCM to release 2006.5, user gets the following error message: "Error associated with msvcr80.dll"
Solution: This error is caused by an outdated release of .NET being installed. Users reporting this error have .NET 1.0 or 2.0. Installing .NET 3.0 will resolve this problem. To obtain the latest .NET installation, visit the Microsoft site. Keywords: None References: None
Problem Statement: In the Specification Blend section of the Full
Solution: report, you will see marginal values for properties that are at a limit. For example, as shown below, the DON (Road Octane) spec is at its limit (MIN DON = 91), therefore it shows a marginal value, in this case of 1.033 (it can also be -1.033, depending on the sign convention chosen for PI values; see solutio...
Problem Statement: What methods are available in ABML to blend D86 T10/T90 temperatures? What are the differences?
Solution: There are 3 different correlations to obtain blended D86 T10/T90 temperatures: ? D86ONE10INDEX, D86ONE90INDEX and their reverse transformations, D86ONE10BLEND, D86ONE90BLEND ? T10INDEX, T50INDEX, T90INDEX ? D86TOPERCENTOFF, D86FROMPERCENTOFF 1) D86ONE10INDEX, D86ONE90INDEX and revers...
Problem Statement: A stream STR is a blending component to a CARB gasoline. The T10, T50, T90 properties in the blend are calculated from the percentage off (e.g. percentage distilled at 130, 150, 170, etc., the properties are typically called 130, 150, etc.) by using ABML correlation D86FROMPERCENTOFF. No apparent sou...
Solution: When using ABML, Aspen PIMS will look for the input properties from the following sources: recursion, T. BLNPROP, T. PCALC. Additionally, if the properties are listed in PGUESS (even though there is no recursion for those properties for the given stream), Aspen PIMS will take them as fixed values (as if they ...
Problem Statement: Warning 639, "CARB Constraints CNX, THC, POT Lower Cased to cnx, thc and pot" may appear when you are using CARBOB2 and CARBOB3 gasolines in the same model and running with XNLP, i.e. you are using types 5-10 together with 12-13 for reformulated gasolines in table BLNSPEC. The message can mislead you...
Solution: Aspen PIMS uses ABML for the reformulated gasoline (CARBOB2 and CARBOB3) calculations, either explicitly (set up by the user) or accessing it for the internal calculations. To avoid name conflicts for the specifications, PIMS will automatically create lower cased cnx, thc and pot specifications for CARBOB2 ga...
Problem Statement: Can you use VBA Automation to control Aspen PIMS as an OLE automation server? What automation methods are available? Where can you get a sample automation code?
Solution: Description: Aspen PIMS can be controlled as an OLE automation server. This means that another Windows program such as Excel or a custom-client program can control the execution of Aspen PIMS with the use of Aspen PIMS automation methods. To use Aspen PIMS automation methods, a basic knowledge of Visual Basic...
Problem Statement: How do I get the MIP Vol / MIP Recipe (Mixed Integer Programming) check boxes to show on the Optimize Blend form? I have selected the same Blending user settings as the demo model. (The demo model shows the check boxes.) The MIP check boxes are available on the Blend form, but not visible on the Opti...
Solution: The reason is that you are not using the Normalized Event tables. In the CONFIG table NORMALIZED_EVENTS is N. If you turn it to Y, there are no events in the screen. You need first to update your database in order that all events will be populate in the new ATOrionEvent tables (using DBUpdate tool) and after ...
Problem Statement: When I tried to Export the Blend information from the Blend Optimization dialog box, the message said the report is exported, but I cannot find it anywhere.
Solution: When you click the EXPORT button to publish the information from the Optimize Blend dialog box , Blend Optimization details are stored in the following tables: ? AB_BLN_EVENTS (output): Store the published list of blend events for the current model. ? AB_BLN_QUALITIES (output):Store the publ...
Problem Statement: Using MBO version 5.2.12 The Component Rundown list shows one (1) day less than the campaign duration. For instance, if the campaign is 7 days long, the rundown list shows only 6 days.
Solution: This is a bug caused by Daylight Savings time. This causes MBO to incorrectly calculate the days to show for the Component Rundowns (see the purpose of this, below). CQ00270550===> This bug has been fixed in MBO v. 5.2.13. Component Rundowns Dialog Box Purpose: Use the Component Rundowns dialog box to displ...
Problem Statement: In Aspen MBO version 3.9.6, we would populate the AB_ Tables via Publish All. We would then use the data in these tables to create our operator reports. In version 4.5.9, Publish All does not populate the AB_ tables. In the Publish menu there is a new item, called Export Blends. Does this feature pop...
Solution: Since MBO v.4.5.0 you can select Blends to Export using the "Select Blends to Export Dialog box" appears when you select: Click Events|Publish|Export Blends. (First, simulate MBO.) Below is an excerpt from the Aspen MBO Help system. For more details please refer to the Help system entry, "Select Blends To...
Problem Statement: Does Aspen Refinery Multi-Blend Optimizar(MBO) use the trend min/max and min working/max working to execute any action? Apparently the MBO tanks/trends limits works differently than Aspen Petroleum Scheduler(Orion) .
Solution: Aspen Refinery Multi-Blend Optimizer (MBO) uses the trend limit min/max and not the minw/maxw to do the Optimization. As far as difference between MBO/SBO and ORION/SBO, there are differences. One is that Orion uses the available volume, MBO uses the trend limit. MBO takes into account component rundown, Orio...
Problem Statement: Several new automation methods have been added which are associated with blend groups with your Aspen MBO .
Solution: Ten new Automation methods are: 1. AddBlendGroup : Use this method to create a blend group 2. AddEventsToBlendGroup :Use this method to add blend events to an existing group 3. AddModifyPropertySpecsToBlendGroup : Use this method to add or modify a property specification associated with an exis...
Problem Statement: I use the Aspen MBO V2006.5 demo to test the Case and State Comparison feature. Aspen MBO gives me information like: Cannot read trend data file for case TEST. Probably file C:\..............\TREND_TEST.DTA does not exit. To create this file you must simulate the case. I do not find the TREND_TEST.DT...
Solution: Use the Case Comparison interface to compare the trend data for multiple cases on a single trend chart. Before using this interface, save the current trend data, which is stored in Trends.dta files. This interface compares the data stored (saved) in the Trends.dta files for the selected cases. To compare two ...
Problem Statement: If the Aspen MBO model is a subset of a larger Aspen Orion model (integrated), then ALL the Event Screens set up for the Orion model will also be listed on the tree in the Aspen MBO model. Many of these will be of no use in Aspen MBO. What needs to be displayed is only those Event Screens that have r...
Solution: GANTT_LIST table has a field (column) called BLENDING (Type: Yes/No) that is used as a Flag to control whether the screen is enabled for Aspen MBO. GANTT_LIST Table Description: Name Type Size Description ID Text 50 ID that identifies an event screen DESCRIPTION Text 255 Description of the event screen Note...
Problem Statement: Some questions about how the Optimization works in Aspen Refinery Multi-Blend Optimizer(MBO)
Solution: 1. If there are no Product Sales prices in the model is there any reason for optimizer to try to blend ceiling amount of products? AT answer: When the product price is zero, the optimizer will try to find the feasible solution that costs the least. It needs to satisfy all fixed shipments and also to keep the ...
Problem Statement: A Project has a requirement of MIP (Mixed Integer Programming) to control the minimum blend quantity for each blend component (component can be "0" or between Min and Max). It is possible to add this feature for MBO?
Solution: The MIP (Mixer Integer Programming) capability has been available in Aspen MBO since release 2006. The MBO Optimizer now incorporates the ability to solve mixed-integer nonlinear optimization problems. Aspen MBO allows discrete decisions through binary (0-1) or semi-continuous variables (0 or between Lower Bo...
Problem Statement: This Knowledge Base article provides steps to resolve the following error message received when trying to create an Aspen Aspen Operations Domain Model (ODM) database in an MS SQL Server 2005: Error: Microsoft SQL Native Client: An error has occurred while establishing a connection to the server. Whe...
Solution: There is a Microsoft Knowledge Base article 914277 (see link below) http://support.microsoft.com/kb/914277/en-us which provides general steps to resolve the above-mentioned error message. Please complete these steps before continuing. In addition, the following ODM specific steps may be necessary if you have ...
Problem Statement: When I change a component property, for example by opening the Properties tab in SBO and changing the SUL of a component then click the CALCULATE / Optimize NLP button I get the following results: 1. Open the Optimizer dialog box- See Property Specifications window 2. Change the SUL value ...
Solution: Aspen MBO is working as designed. The new SBO solver (XNLP solver) was designed to mimic Aspen MBO's results (SBO's results more closely match Aspen MBO"s results). Essentially, it fixes all events around the single blend. It is supposed to take into account all the events that are happening around this singl...
Problem Statement: Tank Property Change Events have been added to Aspen MBO version 2006.5 that allow you to alter the inventory or quality of a tank at a specific point in time during a schedule.
Solution: Use a Tank Property Change Event to alter the inventory or quality of a tank in the middle of a schedule at a specific point in time. This may be necessary, for example, in blending situations where lab results on a specific tank arrive through the day requiring inventory or quality adjustments. Adding a tank...
Problem Statement: Users requested a new error message for Orion and MBO if UBML correlations are used but UBML.dll is not available.
Solution: Warning/error is now generated if UBML correlation(s) used but UMBL.dll is not available. For MBO warning message W1025 and Error E2006 have been added if UBML.dll doesn't exists. Model Error Log report shows the information: For ORION a Model Errors dialog box will pop up when reload simulator/ simulate or p...
Problem Statement: This knowledge base Article discusses the "Error 1402. Could not open key..." message, which can be seen sporadically during the installation of aspenOne Manufacturing Suite products that require Aspen Process Data:
Solution: This error message is related to the Windows Installer not being able to access a particular Windows Registry key, and it may occur even though you are logged in using an Administrator account. This issue can be fixed by changing the permission settings for the registry key in question: NOTE: It is recommende...
Problem Statement: Is it possible to navigate the Aspen Supply Chain Connect (ASCC) Administration Management pages when ASCC is installed on a 64-bit Windows Operating System? When the Aspen Supply Chain Connect | Administration Management page is clicked, the navigation area displays error "Microsoft XML V3 not ins...
Solution: Aspen Supply Chain Connect 2006.5 (and below) is not compatible with Windows 64-bit operating systems. We recommend to install it on 32-bit Windows OS. Informatica does not support 64-bit platforms yet. To view the Informatica PowerCenter 8 Operating System Support information, please visit the Availability...
Problem Statement: Problem Description In PowerCenter 8.1.x, the following exception appears in the Admin Console URL and Catalina.out when you start the Informatica Service: 2007-12-10 11:02:09 ApplicationDispatcher[/adminconsole] Servlet.service() for servlet org.apache.jsp.WEB_002dINF.pages.layouts.LoginTemplate...
Solution: This exception occurs when the CLASSPATH environmental variable has the JAR jsp-api.jar located in a path different from that which is shipped by Informatica. The exception says that the Method VariableResolver is not found. This particular method is available in the JAR jsp-api.jar which is located either in...
Problem Statement: While installing Aspen Supply Chain Connect (ASCC), the user has to provide a service account name as mentioned in the screen shot below: How are you supposed to change the password at specific intervals?
Solution: The user name and password entered in this screen will only be used if there is a Windows service installed with the installed product. If you are installing ASCC 2006.5, you don?t need to worry about this at all since there will be no Windows service installed. This screen is a standard step from AspenOne in...
Problem Statement: This Knowledge Base article shows how to add a company logo to a dashboard display.
Solution: Dashboard Editor only supports images of jpeg and gif format; it does not support bitmap files. The company logo image will need to be converted into a jpeg (preferred) or gif format first. 1) In the RTView Display Builder open the Object Palette. 2) Select any object with a computer and add it to the graphic...
Problem Statement: This Knowledge Base article provides steps to resolve the following error: Could not Invoke Environment Variables due to Setup Problems. which may be encountered in Aspen Business Process Explorer (BPE) Administrator when upgrading to Aspen Framework 2006.5.
Solution: Try re-registering BpeLocalVars.dll file. Following two commands are to be executed from a DOS window in the sequence shown below: regsvr32 /u "C:\Program Files\AspenTech\BPE\BpeLocalVars.dll" regsvr32 "C:\Program Files\AspenTech\BPE\BpeLocalVars.dll" Keywords: None References: None
Problem Statement: Understanding Lab Sample Age Limit
Solution: The following is a brief explanation to understand what Lab Sample Age Limit really does. A user has a lab sample taken every three days. A possible problem is that the CV was going bad before the next lab sample, for this issue the user simply needs to increase the Measurement Timeout for the CV to at least ...
Problem Statement: With all versions prior to v2006.5, the Event Management Rules Engine was a Blaze Rules Engine. This has been replaced by some freeware called Bean Shell that can do just about everything that Blaze could do but for free. If a user really wants to use the old Blaze Engine with 2006.5 does he have any...
Solution: Upgrading to 2006.5 on the same PC should leave the old Blaze Engine in place. If Upgrading to a different PC then the user would need to first install an older version and then Upgrade Keywords: None References: None
Problem Statement: This Knowledge Base article answers several questions regarding Aspen Role-Based Visualization (RBV) v7.1 compatibility with RBV v2006.5.
Solution: Q1: Will the content developed for RBV v2006.5 be fully reusable after we upgrade to RBV v7.1? A1: Yes. Content will be reusable. Users may need to re-enter the deployment variables because of the recent product name changes. Q2: Will RBV v7.1 still run on SharePoint 2007? A2: Yes. Q3: Are there any major cha...
Problem Statement: When you use a web part page as a content page for the Ops Nav site (that is when you use the Aspen Operations Manager editor to add URL attribute to the hierarchy nodes and that URL points to a web part page in a SharePoint library), you will have a problem of nested heading. This problem is caused ...
Solution: To resolve this problem, you will need to install the "RBV Master Page Solution" attached to this Knowledge Base article. This SharePoint solution, once installed and deployed, will provide a feature to change the default Master page to an RBV custom master page. The new RBV custom master page will remove the...
Problem Statement: What is the meaning of the error message below that I received when I tried to run a tool from the Model tree? How do I correct it?
Solution: This means that Aspen Orion cannot find the executable at the path specified in the tool properties. To fix it, right click on the tool in the tree and select properties. You should enter the path to the executable in the Filename field (e.g. C:\Program Files\AspenTech\Templates\Aspen ORION\Demo\Access 00\) a...
Problem Statement: How do I delete parameters in value units from Aspen Petroleum Scheduler?
Solution: Launch Aspen Petroleum Scheduler model, follow up these steps: 1.- Select a Value Unit opening the Flowsheet Interface.Select "Parameters" field 2.- Double click on the row that want to delete, for instance, first row for parameter 1, then the next window appears asking about :insert, delete or cancel, cl...
Problem Statement: When we change an existing crude event or add a new crude event in our model. the system starts simulation . When I modify a Crude Run or Unit Operation event, Excel is always put on top.
Solution: The reason for this behavior is as follows: 1. Crude Transfer Event: In your Excel file (Units.xls) you have defined #SIMULATE into the CRDTRAN sheet . When you use this keyword in Units workbook is because you want to simulate from the last change to the start time of the event before performing the Us...
Problem Statement: Is Aspen Web Fulfillment Management v2006.5 supported on Windows Server 2008 R2 Enterprise Edition 64-bit operating system?
Solution: Aspen Web Fulfillment Management v2006.5 is not supported on Windows 2008 R2 Enterprise Edition 64-bit and it was not officially tested by our QE. Note: Retail v2006.5 software itself (the main application) does not run and is not supported on 64-bit platforms (like Windows Server 2008 R2) Keywords: Web Fulfi...
Problem Statement: How does the IVR call transfer work?
Solution: If a customer calls during terminal operating hours and selects the *0# option, the caller is transferred to the first of the Voice Fulfillment Management phone numbers defined in Terminal Setup. If there is no response, the caller is transferred to subsequent phone numbers according to the sequence defined i...
Problem Statement: I need information (demo model or documentation) to model a distribution network of a company including a complicated business process : integer variables, new constraints, and additions to the optimization objective function. Can you provide me with some documentation?
Solution: Here are 3 sample models around Incentive pay : ? DPO Problem 10B - Incentive Pay.zip ? DPO Problem 10C- Fixed FEE and Variable.zip ? DPO Problem 10D- Take or Pay.zip The attached presentation called "Class Problem 10 to 10d" contains details about what the models are trying to do . Ke...
Problem Statement: Sometimes it is difficult in PPIMS to achieve the desired targets for the inventoried products without forcing these inventories in table PINV by setting MIN=MAX=TARGET. Here are some considerations that aim to explain the different inventory configurations that can appear, and how to deal with them....
Solution: We will review how the inventory policy is defined in terms of the optimization matrix. Based on that information, we will review how to operate on these matrix coefficients to achieve the desired results for the inventory. Relation between matrix coefficients and inventory policy For product abc, the main co...
Problem Statement: In the Matrix Analysis Program, when looking at the final matrix of my model, I see two values reported: Row Activity and Row Activity Sum. What are these two values and where do they come from?
Solution: While these two entries target the same thing, they come from two different places. The Row Activity is read from the database (or .xlp file in AO), while the Row Activity Sum is calculated based on the sum of the coefficients*activity for all row entries. Due to round-off errors and differences in storage me...
Problem Statement: At the end of an Aspen PIMS run, when it tries to generate the reports, the following error message is displayed: The reports are not generated. What is the cause and how can it be fixed?
Solution: Starting with Aspen PIMS 2006, it requires at least Microsoft .NET version 2 to generate the reports. This problem is related to an incorrect version or a corrupt installation of Microsoft .NET. To solve it try the following steps: 1. First check in the Aspen PIMS installation folder if there is a file call...
Problem Statement: Table CRDMIX and CRDBLEND, are both tables that define mixtures of crude oils. What is the difference between table CRDMIX and CRDBLEND from the function angle?
Solution: Table CRDBLEND is available in both standard and periodic models, Table CRDMIX is available in periodic model only. Regarding the LP structural difference, if CRDBLEND is defined, PIMS automatically generates mixed assay data. An ESTxxx row for the mix must be defined in table CRDDIST so the crude mix which...
Problem Statement: This knowledge base article describes why you may get an excel warning message during report generation in Aspen PIMS.
Solution: The warning message shown in the figure below pops up during report generation in Aspen PIMS if the user does not have sufficient privileges for the working folder. This can be verified by inspecting the security profile under Properties | Security dialog. If the Full Control item is not checked...
Problem Statement: Can MINOBJ and other Aspen PIMS settings be changed from Table CASE?
Solution: Yes, many Aspen PIMS settings can be changed from table CASE by using reference to TABLE SETTINGS. An example of how to do this is shown below. CASE 2 Modify Model Settings TABLE SETTINGS TEXT VALUE GenerateOn 1 MINOBJ 850 VOL BBLS WGT MTONS Not all Aspen PIMS model settings can be changed t...
Problem Statement: The McAfee Antivirus program is erroneously flagging the AspenTech SLMCommute.exe file as a virus for users who have updated to the McAfee Virus Scan Dat file #5353 which was released on 4-Aug-2008.
Solution: McAfee released an updated Virus Scan dat file (Dat file #5353) on 4-Aug-2008. This updated Virus Scan data file erroneously flags one of our license manager commuter license utility file (SLMCommute.exe) as a virus. This can cause this utility file to be deleted from a user's machine. AspenTech has worked wi...
Problem Statement: Pucks for the filling work center are left on Phantoms during the "Rescheduling " function. This is illustrated below:
Solution: When bringing in new production into the Scheduling model and running the "Reschedule" function the filling pucks are not being scheduled and remain on the phantom facility. This was occurring due to an incorrect setting You need to change INDSV?s code size to 5. Go into the set catalog, find INDSV, open its...
Problem Statement: After installing Supply Planner on a new machine, cannot get SQL connection working (Oracle 8.1.x)
Solution: In the ODBC Data Source Administrator, Aspen uses the System DSN tab, not the User DSN tab. You must ensure it is configured with the correct service name in the User DSN tab and with the incorrect service name in the System DSN tab. Keywords: None References: None
Problem Statement: In the help file, the SEQ field in EV_DAILY is described as "Number that uniquely identifies an event. Note: This number is assigned by the system and appears as the X_SEQ value in table EVENTS. Set as index (duplicates allowed) to improve performance during publishing" Should this read ".. in table ...
Solution: Orion Help documentation file should refer _EVENTS instead of EVENTS (or ATORIONEvents). The unique numbers in the published _EVENTS table are completely independent of the numbers in the EVENTS table. When publishing _EVENTS the X_SEQ column is initially copied directly from EVENTS. The Z_SEQ values are auto...
Problem Statement: I am testing pulling a capacity row activity, P row value and a column activity in the Aspen PIMS to Aspen Petroleum Scheduler (Aspen Orion) interface model. I am trying to pull each of the following to parameter #1 of an Orion XPM unit however after running the model it keeps getting "zeros" for par...
Solution: Remove the mapping tables in "access" format and create them in "excel sheet" format. Also, remove all "access" tables in the mapping section. It only works with excel. We have a functionality where we write PIMS data to excel and read back the modified value from excel. This really cannot work in access. Thi...
Problem Statement: How to import the Crude composition for a Crude Receipt into the staging table, ORION_MGR_EVENT_IMPORT. Does the crude composition get populated into a field in this table or another table? If it is the ORION_MGR_EVENT_IMPORT table, what field and what format?
Solution: Crude composition is populated into the staging table called : ORION_MGR_EVPROP_IMPORT. You have to put the same APPLICATION_ID and MOVEMENT_ID appear in table ORION_MGR_EVENT_IMPORT and after , on field " PROP_ID" (type: Text; NotNull) you should put crude composition . See the following example: 1.- If you ...
Problem Statement: _TANKS does not include a published crude weight for the first day in version 2006.5. For Process tanks, there is a weight published for the first day even though TNKINV does not contain a weight value. This is not true for Crude tanks, where there is no weight published for the first day. Sometimes ...
Solution: For this purpose was added in CONFIG table a switch called PUBLISH_AT_10_SEC Value:Y, that allows to publish WGT property for Crudes on the Model Start Date. Keywords: -_TANKS table -Publish data -CONFIG table References: None
Problem Statement: Aspen Petroleum Scheduler takes around 45 minutes and sometimes the timeout error appears when publishing data( SQL server)
Solution: The Ethernet Port Configuration can be a possible cause of this behavior. Please, check the server and the Ethernet port configuration. For example, if it is set to 100Full then switch it to "Auto" and it will be running at "Gig" Full. It should be fixed this issue. Keywords: - Publish - Ethernet Port Configu...
Problem Statement: Can you please indicate if the CONFIG keywords SYS, VBDLL and VAC are used, and when I should see values for them? I don't see values for them in the CONFIG table in my models but in the help file I see the following: VAC: Number of Vacuum Cuts VBDLL: Registered VB DLL File SYS : System Directory
Solution: VAC and SYS are no longer used. VBDLL is the name of the VB unit file and this defines that. The default is OrionVb.dll. The documentation will be updated in version 7.1 with this information ("Setting Keywords: " for CONFIG table) Keywords -CONFIG table - Settings References: None
Problem Statement: How does Orion XT update events in a multi-user environment?
Solution: Here is a summary of some different situations: Basis: User 1 - is working in the 1st 5 days User 2 - is working in day 6 and beyond (and includes days 1 to 5) User 1 and User 2 are working in the same case Situation # 1: User 2 updates some events and does not save. User 1 updates different events and then...
Problem Statement: Is it possible to disable a tank in Aspen Orion XT?
Solution: A tank cannot be disabled directly in Aspen Orion XT. However, Aspen Orion XT has the capability to assign service to a tank (Material service Event ) and one could assign a tank service to be out of service. This would not, however, prevent the tank from showing up on a drop down list on an event dialog, for...
Problem Statement: While using Aspen Orion XT 2006.5 to open a model made with Aspen Orion XT 2006 or earlier, you may see the following warning message.
Solution: This warning message indicates that you should use the Normalized Event Table option and your model requires upgrading. Step 1: If you want to retain the existing un-normalized event table, then open Config table in the Orion Model, and add the following record as suggested in the message. Step 2: Now save ...
Problem Statement: When in a Trend Limit Dialog Box for a given Event Screen, if the user sets a trend limit for a tank that is not shown in this dialog box, then the trend limits that come up are not the ones for the tank specified, but for the first tank in the dialog box. Why?
Solution: Essentially there are 3 sources of the trend limit, table TREND_LIMIT, TREND_SCREEN and TANKS and the pecking order is as listed. When you change an existing trend variable to another tank that isn't already on the trend list for that screen then the new tank assumes the trend limits of the original tank rath...
Problem Statement: Orion/SBO crashes for Gasoline blending Event Screen after apply Optimize button.
Solution: The problem here is that the number of specifications in the blend exceeded 50 which is the hard limit for the blends. In v7.2 the following error message was added when this happen: "The maximum number of specs for a blend is 50. Minimum specs of 0.0 and maximum specs of EMPTY are ignored and thus not counte...
Problem Statement: In my database I have a custom table. It is possible to link this table to Aspen Aspen Orion XT so that the information can be updated by the model administrator directly from Aspen Orion XT?
Solution: The custom table can be added to the database table tree in Aspen Orion XT by adding a record in the MODEL_TABLES table. This would allow the administrator to modify the table directly from Orion. If the category for the table is set to ADMIN in MODEL_TABLES then only someone in the ADMIN group may see this b...
Problem Statement: It is possible to specify a timeout on the adapter requests when using web services? E.g. when the Aspen Orion scheduler hits import inventories and qualities can they specify in a config file somewhere how long it will wait? If not what is the current timeout?
Solution: There is a timeout setting which can be specified for every request service. Select the Request Services folder | Request_Supply_Demand - Request Tab, then change the timeout. Keywords: - Timeout - Orion Adapter References: None
Problem Statement: Users may see the warning message "ADAPTER INITIALIZATION FAILED" when trying to import Events into Orion (Integration| Import Events) even if they are NOT using the adapters.
Solution: This can happen if during the Orion installation procedure, the adapter components option was selected by error. To fix this problem follow up these steps: 1. In CONFIG table, verify/add the register called "CHECK_OMII_REGISTRY" with value = 'N' 2. Remove/delete from the following: 2.1.- C:\WINNT\Assembly...
Problem Statement: Is it possible to display Crude Properties other than API and SUL in the standard "Crude Yields and Properties" Dialog Box? (via "Events", "Show Crude Yields" in the Menu Bar)
Solution: The answer is yes. Additional Crude Properties may be defined in data table CRUDES. The following procedure will illustrate how to accomplish this. 1.-Open table CRDPROPS : 2.-Add the property that you want to have ( CRDID (name of the crude), PROPID (CRD), PROPID (name of property, check that it already ex...
Problem Statement: It would be very helpful if the Scheduler had another way to quickly detect problems like overage and shortages in addition to the red /green dots (points at which bounds have not been maintained) shown on the Trend Screens (Gantt interface).
Solution: Aspen Orion XT has a feature called "Inventory Problems" that allows you to display inventory problems caused by events in your schedule. To access the "Inventory Problems" dialog box do the following: ? ...
Problem Statement: When importing a PIMS Unit Operation Event to ORION using PIMS to Orion interface, the PIMS event won't delete preview event and will display duplicate event on screen.(Ex. VDU has 09/01 to 10/15 and import PIMS event for VDU from 10/01 to 10/30, after, go to VDU event screen and check. The VDU event...
Solution: PIMS to Orion interface will only delete an existing (previous) Orion event if the Orion event start and stop exactly matches the imported PIMS event start and stop. For more information about PIMS-Orion interface, there is a full help file called ORIONPIMSInt.chm. This file should be in the same location as ...
Problem Statement: The IsConnected property returns true in ACM when a port of a submodel is linked. If the model is exported, the property IsConnected returns false in Aspen Plus. This is causing some problem in ACM below v7.1. The problem does not occur in ACM v7.1 and higher We have the following: model acm_noop i...
Solution: This was a deficiency of the IsConnected property in ACM older than v7.1. This is not a problem with v7.1 and higher versions. The attached file shows the expected behaviour as per design. The rest of this section applies only to versions older than v7.1, which are no longer supported. This is only for hist...
Problem Statement: This knowledge base article describes the possible causes for the following error message which can be logged in the cimio_msg.log file. CIMIO_SOCK_GETSERV_FAIL, Error looking up service name WNT Error=11004 The requested name is valid and was found in the database, but it does not have the correct ...
Solution: This error message usually indicates that there is a problem with the entries in the services file. The services file is located in the following folder: WINDOWS\system32\drivers\etc Ensure that the services listed in your services file match the entries in your cimio_logical_devices.def file. Ensure that ...
Problem Statement: Where are my Aspen PIMS Family Sample Models?
Solution: In the 2006.5 release of Aspen PIMS (version 17.5), the location of the Aspen PIMS Family Model templates has been moved from <Program Installation Directory>\Aspentech\Templates\<Application Name>\<Files> to C:\Documents and Settings\All Users\Shared Documents\AspenTech\<Application Name>\<Files> Please note...
Problem Statement: How do I calculate the activity coefficient for a stream in Aspen HYSYS through automation?
Solution: Currently, there is not a direct way to get the NRTL activity coefficient from Aspen HYSYS. Although Aspen HYSYS internally calculates them, it is not exposed to user interface. It is planned to be available in the future release. In attached file, MS excel macro is written to obtain the BIPs' value for all c...
Problem Statement: The purpose of this solution is to provide more information about various XNLP/XSLP settings and highlight which settings are most important. There are many settings related to the nonlinear model building (XNLP) and solving (XSLP) in PIMS. Whatever the setting is, our goal is to come up with a def...
Solution: XNLP Settings XNLP Settings are the settings used when generating the nonlinear model formulation as described in the XMPS.mps file. Remember that the model is separate from the solver in PIMS-AO (Advanced Optimization). Advanced Tab ? Use Tighter Bounds on Qualities A detailed explanation of th...
Problem Statement: Is it possible to model a sulfuric acid process?
Solution: Attached is an example of this process. This example will run in Aspen Plus 2006.5 and higher. Introduction This model simulates the production process of sulfuric acid from sulfur in a typical double absorption plant. The model includes the following features: ? A set of electrolyte components for th...