readily obtained from multiple retail outlets are not considered to be special accessories and are not required to be marketed with the equipment. The manual included with the equipment must specify what additional components or accessories are required to be used in order to ensure compliance with this part, and it is... |
including any accessories or components marketed with the equipment, must comply with the regulations.
[54 FR 17714, Apr. 25, 1989, as amended at 68 FR 68545, Dec. 9, 2003; 82 FR 50831, Nov. 2, 2017]
<div |
class="section" id="15.29">
§ 15.29 Inspection by the Commission.
(a) Any equipment or device subject to the provisions of this part, together with any certificate, notice of registration or any technical data required to be kept on file by the operator, supplier or party responsible for compliance of the device shal... |
ailable for inspection by a Commission representative upon reasonable request.
(b) The owner or operator of a radio frequency device subject to this part shall promptly furnish to the Commission or its representative such information as may be requested concerning the operation of the radio frequency device.
<spa... |
ss="paren">(c) The party responsible for the compliance of any device subject to this part shall promptly furnish to the Commission or its representatives such information as may be requested concerning the operation of the device, including a copy of any measurements made for obtaining an equipment authorization or de... |
time to time, may request the party responsible for compliance, including an importer, to submit to the FCC Laboratory in Columbia, Maryland, various equipment to determine that the equipment continues to comply with the applicable standards. Shipping costs to the Commission's Laboratory and return shall be borne by t... |
ta-reference="54 FR 17714">54 FR 17714, Apr. 25, 1989, as amended at 82 FR 50831, Nov. 2, 2017]
§ 15.31 Measurement standards.
(a) The following measurement procedu |
res are used by the Commission to determine compliance with the technical requirements in this part. Except where noted, copies of these procedures are available from the Commission's current duplicating contractor whose name and address are available from the Commission's Consumer and Governmental Affairs Bureau at 1-... |
(2) Unlicensed Personal Communications Service (UPCS) devices are to be measured for compliance using ANSI C63.17-2013: “American National Standard Methods of Measurement of the Electromagnetic and Operational Compatibility of Unlicensed Personal Communications Services (UPCS) Devices” (incorporated by reference, see... |
3)">
(3) Other intentional radiators must be measured for compliance using the following procedure: ANSI C63.10-2020 (incorporated by reference, see § 15.38).
(4) Unintentional radiators are to be measured for |
compliance using the following procedure excluding clauses 4.5.3, 4.6, 6.2.13, 8.2.2, 9, and 13: ANSI C63.4-2014 (incorporated by reference, see § 15.38).
Note 1 to paragraph (a)(4):
Digital devices tested to show compliance with the provisions of § 15.109(g)(2) must be tested following the ANSI C63.4-2014 procedure ... |
title-47/section-15.31#p-15.31(a)(4)" class="cfr external">paragraph (a)(4) of this section.
(b) All parties making compliance measurements on equipment subject to the requirements of this part are urged to use these measurement procedures. Any party using other procedures should ensure that such other procedures c... |
he description of the measurement procedure used in testing the equipment for compliance and a list of the test equipment actually employed shall be made part of an application for certification or included with the data required to be retained by the party responsible for devices authorized pursuant to Supplier's Decl... |
class="cfr external">§§ 15.255 and 15.256, for swept frequency equipment, measurements shall be made with the frequency sweep stopped at those frequencies chosen for the measurements to be reported.
(d) Field strength measurements shall be made, to the extent possible, on an open area test site. Test sites other tha... |
oyed if they are properly calibrated so that the measurement results correspond to what would be obtained from an open area test site. In the case of equipment for which measurements can be performed only at the installation site, such as perimeter protection systems, carrier current systems, and systems employing a “l... |
div>
(e) For intentional radiators, measurements of the variation of the input power or the radiated signal level of the fundamental frequency component of the emission, as appropriate, shall be performed with the supply voltage varied between 85% and 115% of the nominal rated supply voltage. For battery operated equi... |
ata-title="15.31(f)">(f) To the extent practicable, the device under test shall be measured at the distance specified in the appropriate rule section. The distance specified corresponds to the horizontal distance between the measurement antenna and the closest point of the equipment under test, support equipment or int... |
nt under test. The equipment under test, support equipment and any interconnecting cables shall be included within this boundary.
(1) At frequencies at or above 30 MHz, measurements may be performed at a distance other than what is specified provided: measurements are not made in the near field except where it can be... |
nstrated that the signal levels needed to be measured at the distance employed can be detected by the measurement equipment. Measurements shall not be performed at a distance greater than 30 meters unless it can be further demonstrated that measurements at a distance of 30 meters or less are impractical. When performin... |
ts).
(2) At frequencies below 30 MHz, measurements may be performed at a distance closer than that specified in the regulations; however, an attempt should be made to avoid making measurements in the near field. Pending the development of an appropriate measurement procedure for measurements performed below 30 MHz, ... |
specified distance by either making measurements at a minimum of two distances on at least one radial to determine the proper extrapolation factor or by using the square of an inverse linear distance extrapolation factor (40 dB/decade). This paragraph (f) shall not apply to Access BPL devices operating below 30 MHz.
... |
evices operating below 30 MHz, measurements shall be performed at the 30-meter reference distance specified in the regulations whenever possible. Measurements may be performed at a distance closer than that specified in the regulations if circumstances such as high ambient noise levels or geographic limitations are pre... |
slant-range distance defined in § 15.3(hh) of this part. As an alternative, a site-specific extrapolation factor derived from a straight line best fit of measurements of field strength in dBµV/m vs. logarithmic distance in meters for each carrier frequency, as determined by a linear least squares regression calculatio... |
on. Site-specific determination of the distance extrapolation factor shall not be used at locations where a ground conductor is present within 30 meters if the Access BPL signals are on the neutral/grounded line of a power system.
(4) The applicant for a grant of certification shall specify the extrapolation method ... |
ormity, this information shall be retained with the measurement data.
(5) When measurement distances of 30 meters or less are specified in the regulations, the Commission will test the equipment at the distance specified unless measurement at that distance results in measurements being performed in the near field. W... |
test the equipment at a closer distance, usually 30 meters, extrapolating the measured field strength to the specified distance using the methods shown in this section.
(6) Measurements shall be performed at a sufficient number of radials around the equipment under test to determine the radial at which the field str... |
asured shall be reported in the equipment authorization report. This paragraph shall not apply to Access BPL equipment on overhead medium voltage lines. In lieu thereof, the measurement guidelines established by the Commission for Access BPL shall be followed.
(g) Equipment under test shall be positioned and adjust... |
in such a manner as to maximize the level of the emissions. For those devices to which wire leads may be attached by the operator, tests shall be performed with wire leads attached. The wire leads shall be of the length to be used with the equipment if that length is known. Otherwise, wire leads one meter in length sha... |
">) A composite system, as defined in § 2.947(f) of this chapter, that incorporates a carrier current system shall be tested as if the carrier current system were incorporated in a separate device; that is, the device shall be tested for compliance with whatever rules would apply to the device were the carrier current ... |
s="indent-1" data-title="15.31(i)">(i) If the device under test provides for the connection of external accessories, including external electrical input signals, the device shall be tested with the accessories attached. The device under test shall be fully exercised with these external accessories. The emission tests s... |
ting conditions. In the case of multiple accessory external ports, an external accessory shall be connected to one of each type of port. Only one test using peripherals or external accessories that are representative of the devices that will be employed with the equipment under test is required. All possible equipment ... |
ass="paren">(j) If the equipment under test consists of a central control unit and an external or internal accessory(ies) (peripheral) and the party declaring compliance of the equipment or applying for a grant of equipment authorization manufactures or assembles the central control unit and at least one of the accesso... |
does not manufacture or assemble. If the party declaring compliance of the equipment or applying for a grant of equipment authorization does not manufacture or assemble the central control unit and at least one of the accessory devices that can be used with that control unit or the party can demonstrate that the centra... |
r. Only one test using peripherals or accessories that are representative of the devices that will be employed with the equipment under test is required. All possible equipment combinations are not required to be tested. The accessories or peripherals connected to the device being tested shall be unmodified, commercial... |
ained in a single enclosure or in separate enclosures connected by wire or cable) shall be measured for compliance with the technical standards of this part in accordance with the procedures in § 2.947(f) of this chapter. For digital devices that consist of a combination of Class A and Class B devices, the total combin... |
not be employed for obtaining a grant of equipment authorization or declaring compliance of a Class B digital device. However, if the digital device combination consists of a Class B central control unit, e.g., a personal computer, and a Class A internal peripheral(s), it must be demonstrated that the Class B central ... |
n">(l) Measurements of radio frequency emissions conducted to the public utility power lines shall be performed using a 50 ohm/50 uH line-impedance stabilization network (LISN).
(m) Measurements on intentional radiators or receivers, other than TV broadcast receivers, shall be performed and, if required, reported fo... |
ng at the number of frequencies in each band specified in the following table:
Frequency range over which device operates
Number of frequencies
Location in the range of operation
1 MHz or less
1
Middle.
1 to 10 MHz
2
1 near top and 1 near bottom.
More than 10 MHz
<td c |
lass="align-right">3
1 near top, 1 near middle and 1 near bottom.
(n) Measurements on TV broadcast receivers shall be performed with the receiver tuned to each VHF frequency and also shall include the following oscillator frequencies: 520, 550, 600, 650, 700, 750, 800, 850, 900 and 931 MHz. If measurements cannot ... |
ause of the presence of signals from licensed radio stations or for other reasons to be detailed in the measurement report, measurements shall be made with the receiver oscillator at a nearby frequency. If the receiver is not capable of receiving channels above 806 MHz, the measurements employing the oscillator frequen... |
missions from unintentional radiators which are attenuated more than 20 dB below the permissible value need not be reported unless specifically required elsewhere in this part.
(p) In those cases where the provisions in this section conflict with the measurement procedures in paragraph (a) of this section and the pr... |
ter June 23, 1989, the provisions contained in the measurement procedures shall take precedence.
(q) As an alternative to § 15.256, a level probing radar (LPR) may be certified as an intentional radiator by showing compliance with the general provisions for operation under part 15 subpart C of this chapter, provided... |
ce with the provisions in either paragraphs (q)(1) or (2) of this section. Compliance with the general provisions for an intentional radiator may require compliance with other rules in this part, e.g., §§ 15.5, 15.31, and <a href="/on/2024-04-11/title-47/section-15.35" class="cfr |
external">15.35, etc., when referenced.
(1) An LPR device intended for installation inside metal and concrete enclosures may show compliance for radiated emissions when measured outside a representative enclosure with the LPR installed inside, in accordance with the measurement guidelines established by the Commissio... |
is closed when the radar device is operating. Care shall be taken to ensure that gaskets, flanges, and other openings are sealed to eliminate signal leakage outside of the structure. The responsible party shall take reasonable steps to ensure that LPR devices intended for use in these types of enclosures shall not be i... |
id="p-15.31(q)(2)">(2) Except as provided in paragraph (q)(1) of this section, an LPR device shall be placed in testing positions that ensure the field strength values of the radiated emissions are maximized, including in the main beam of the LPR antenna.
[<a href="https://www.federalregister.gov/citation/54-FR-17714... |
ence" data-reference="54 FR 17714">54 FR 17714, Apr. 25, 1989, as amended at 56 FR 13083, Mar. 29, 1991; 57 FR 24990, June 12, 1992; 57 FR 33448, July 29, 1992; <a href="https://www.federalregister.gov/citation/58-FR-37430" class="fr-reference" |
data-reference="58 FR 37430">58 FR 37430, July 12, 1993; 58 FR 51249, Oct. 1, 1993; 61 FR 14502, Apr. 2, 1996; 62 FR 41881, Aug. 4, 1997; <a href="https://www.federalregister.gov/citation/62-FR-45333" class="fr-reference" data-reference="62 FR 4 |
5333">62 FR 45333, Aug. 27, 1997; 63 FR 36602, July 7, 1998; 63 FR 42278, Aug. 7, 1998; 65 FR 58466, Sept. 29, 2000; 68 FR 68545 |
, Dec. 9, 2003; 69 FR 54034, Sept. 7, 2004; 70 FR 1373, Jan. 7, 2005; 76 FR 71908, Nov. 21, 2011; 77 FR 4913, Feb. 1, 2012; <a href="htt |
ps://www.federalregister.gov/citation/77-FR-43013" class="fr-reference" data-reference="77 FR 43013">77 FR 43013, July 23, 2012; 79 FR 12677, Mar. 6, 2014; 80 FR 2838, Jan. 21, 2015; 80 FR 33447, June 12, 2015; <a href="https://www.federalregister |
.gov/citation/82-FR-50831" class="fr-reference" data-reference="82 FR 50831">82 FR 50831, Nov. 2, 2017; 88 FR 47394, July 24, 2023; 88 FR 67115, Sept. 29, 2023]
§ 15.32 Test procedures for CPU boards and compute |
r power supplies.
Power supplies and CPU boards used with personal computers and for which separate authorizations are required to be obtained shall be tested in accordance with the specific procedures published or otherwise authorized by the Commission.
[82 FR 50832, Nov. 2, 2017]
§ 15.33 Frequenc |
y range of radiated measurements.
(a) For an intentional radiator, the spectrum shall be investigated from the lowest radio frequency signal generated in the device, without going below 9 kHz, up to at least the frequency shown in this paragraph:
(1) If the intentio |
nal radiator operates below 10 GHz: to the tenth harmonic of the highest fundamental frequency or to 40 GHz, whichever is lower.
(2) If the intentional radiator operates at or above 10 GHz and below 30 GHz: to the fifth harmonic of the highest fundamental frequency or to 100 GHz, whichever is lower.
<span |
class="paren">(3) If the intentional radiator operates at or above 30 GHz: to the fifth harmonic of the highest fundamental frequency or to 200 GHz, whichever is lower, unless specified otherwise elsewhere in the rules.
(4) If the intentional radiator operates at or above 95 GHz: To the third harmonic of the highest... |
specified otherwise elsewhere in the rules.
(5) If the intentional radiator contains a digital device, regardless of whether this digital device controls the functions of the intentional radiator or the digital device is used for additional control or function purposes other than to enable the operation of the inten... |
04-11/title-47/section-15.33#p-15.33(a)(1)" class="cfr external">paragraphs (a)(1) through (4) of this section or the range applicable to the digital device, as shown in paragraph (b)(1) of this section, whichever is the higher frequency range of investigation.
(b<span class="p |
aren">) For unintentional radiators:
(1) Except as otherwise indicated in paragraphs (b)(2) or (b)(3) of this section, for an unintentional radiator, including a digital device, the spectrum shall be investigated from the lowest radio frequen |
cy signal generated or used in the device, without going below the lowest frequency for which a radiated emission limit is specified, up to the frequency shown in the following table:
Highest frequency generated or used in the device or on which the device operates or tunes (MHz)
Upper frequency of measurement rang... |
="align-left">108-500
2000.
500-1000
5000.
Above 1000
5th harmonic of the highest frequency or 40 GHz, whichever is lower.
(2) A unintentional radiator, excluding a digital device, in which the highest frequency generated in the |
device, the highest frequency used in the device and the highest frequency on which the device operates or tunes are less than 30 MHz and which, in accordance with § 15.109, is required to comply with standards on the level of radiated emissions within the frequency range 9 kHz to 30 MHz, such as a CB receiver or a dev... |
or used in the device, without going below 9 kHz (25 MHz for CB receivers), up to the frequency shown in the following table. If the unintentional radiator contains a digital device, the upper frequency to be investigated shall be that shown in the table below or in the table in paragraph (b)(1) of this section, as bas... |
ency generated or used in the device or on which the device operates or tunes (MHz)
Upper frequency of measurement range (MHz)
Below 1.705
30
1.705-10
400
10-30
500
(3)</span |
> Except for a CB receiver, a receiver employing superheterodyne techniques shall be investigated from 30 MHz up to at least the second harmonic of the highest local oscillator frequency generated in the device. If such receiver is controlled by a digital device, the frequency range shall be investigated up to the high... |
1) of this section.
(c) The above specified frequency ranges of measurements apply to the measurement of radiated emissions and, in the case of receivers, the measurement to demonstrate compliance with the antenna conduction limits specified in § 15.111. The frequency range of measurements for AC power line conduct... |
href="/on/2024-04-11/title-47/section-15.107" class="cfr external">§§ 15.107 and 15.207 and applies to all equipment subject to those regulations. In some cases, depending on the frequency(ies) generated and used by the equipment, only signals conducted onto the AC power lines are required to be measured.
(d) Partic... |
armonics and subharmonics of the fundamental frequency as well as to those frequencies removed from the fundamental by multiples of the oscillator frequency. Radiation at the frequencies of multiplier states should also be checked.
[54 FR 17714, Apr. 25, 1989, as amended at 61 FR 14502, Apr. 2, 1996; <a href="https://... |
ter.gov/citation/63-FR-42278" class="fr-reference" data-reference="63 FR 42278">63 FR 42278, Aug. 7, 1998; 84 FR 25691, June 4, 2019]
§ 15.35 Measurement detector functions and bandwidths.
The conducted and radiated emission limits shown in this part are based on the following, unless otherwise specified in this par... |
(a) On any frequency or frequencies below or equal to 1000 MHz, the limits shown are based on measuring equipment employing a CISPR quasi-peak detector function and related measurement bandwidths, unless otherwise specified. The specifications for the measuring instrumentation using the CISPR quasi-peak detector can ... |
class="cfr external">§ 15.38). As an alternative to CISPR quasi-peak measurements, the responsible party, at its option, may demonstrate compliance with the emission limits using measuring equipment employing a peak detector function as long at the same bandwidth as indicated for CISPR quasi-peak measurements are emplo... |
n limits are based on the use of measurement instrumentation employing an average detector function. Unless otherwise specified, measurements above 1000 MHz shall be performed using a minimum resolution bandwidth of 1 MHz. When average radiated emission measurements are specified in this part, including average emissio... |
.252" class="cfr external">15.252, 15.253(d), 15.255, 15.256, and 15.509 through 15.519, the limit on peak radio frequency emissions is 20 dB above the maximum permitted average emission limit applicable to the equ |
ipment under test. This peak limit applies to the total peak emission level radiated by the device, e.g., the total peak power level. Note that the use of a pulse desensitization correction factor may be needed to determine the total peak emission level. The instruction manual or application note for the measurement in... |
otherwise specified, e.g., §§ 15.255 and 15.256(l)(5), when the radiated emission limits are expressed in terms of the average value of the emission, and pulsed operation is employed, the measurement field strength shall be determined by averaging over one complete pulse train, including blanking intervals, as long as ... |
than 0.1 seconds) or in cases where the pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the average absolute voltage during a 0.1 second interval during which the field strength is at its maximum value. The exact method of calculating the average field strength shall be submitted ... |
ce="82 FR 50832">82 FR 50832, Nov. 2, 2017, as amended at 88 FR 47394, July 24, 2023]
§ 15.37 Transition provisions for compliance with this part.
(a) The manufactu |
re or importation of scanning receivers, and frequency converters designed or marketed for use with scanning receivers, that do not comply with the provisions of § 15.121 shall cease on or before October 25, 1999. Effective July 26, 1999, the Commission will not grant equipment authorization for receivers that do not c... |
United States, or imported into the United States, prior to October 25, 1999.
(b) Effective October 16, 2002, an equipment approval may no longer be obtained for medical telemetry equipment operating under the provisions of § 15.241 or § 15.242. The requirements for obtaining an a |
pproval for medical telemetry equipment after this date are found in subpart H of part 95 of this chapter.
(c) All radio frequency devices that are authorized on or after July 12, 2004 under the certification, or Supplier's Declaration of Conformity procedures (or the prior verification or declaration of conformity ... |
mply with the conducted limits specified in § 15.107 or § 15.207 as appropriate. All radio frequency devices that are manufactured or imported on or after July 11, 2005 shall comply with the conducted limits specified in § 15.107 or § 15.207, as appropriate. Equipment authorized, imported or manufacture |
d prior to these dates shall comply with the conducted limits specified in § 15.107 or § 15.207, as appropriate, or with the conducted limits that were in effect immediately prior to September 9, 2002.
(d) Radar detectors manufactured or imported after August 28, 2002 and marketed |
after September 27, 2002 shall comply with the regulations specified in this part. Radar detectors manufactured or imported prior to January 27, 2003 may be labeled with the information required by § 2.925 of this chapter and § 15.19(a) on the individual equipment carton rather than on the device, and are exempt from ... |
/div>
(e) U-NII equipment operating in the 5.25-5.35 GHz band for which applications for certification are filed on or after July 20, 2006 shall comply with the DFS and TPC requirements specified in § 15.407. U-NII equipment operating in the 5.25-5.35 GHz band that are imported or marketed on or after July 20, 2007 sh... |
§ 15.407.
(f) All Access BPL devices that are manufactured, imported, marketed or installed on or after July 7, 2006, shall comply with the requirements specified in subpart G of this part, including certification of the equipment.
<p class="in |
dent-1" data-title="15.37(g)">(g) The manufacture or importation of auditory assistance devices that operate in the 72.0-73.0 MHz, 74.6-74.8 MHz, and 75.2-76.0 MHz bands that do not comply with the requirements of § 15.237(c) shall cease on or before July 11, 2016. Effective January 12, 2015, equipment approval will no... |
75.2-76.0 MHz bands that do not comply with the requirements of § 15.237(c). These rules do not prohibit the sale or use of authorized auditory assistance devices that operate in the 72.0-73.0 MHz, 74.6-74.8 MHz, and 75.2-76.0 MHz bands manufactured in the United States, or imported into the United States, prior to Jul... |
ve June 2, 2015 devices using digital modulation techniques in the 5725-5850 MHz bands will no longer be certified under the provisions of § 15.247. The technical requirements for obtaining certification after this date for digitally modulated devices and the digitally modulated portion of hybrid devices are found in s... |
"/on/2024-04-11/title-47/section-15.247" class="cfr external">§ 15.247. Effective June 2, 2016 systems using digital modulation techniques in the 5725-5850 MHz band certified under the provisions of § 15.247 may no longer be imported or marketed within the United States.
(i) As of December 26, 2017, wireless microph... |
certification is filed must comply with the requirements of § 15.236. Manufacturing and marketing of wireless microphones that would not comply with the rules for operation in § 15.236 must cease no later than September 24, 2018. Only wireless microphones certified for operation under this part may be operated under th... |
archy">(j) White space devices which are approved by Telecommunication Certification Bodies beginning [six months after the effective date of the rules] shall comply with the database re-check requirements in § 15.711(h) of this part. White space devices that are in operation, imported or marketed beginning [six months... |
="indent-1" data-title="15.37(k)">(k) Disclosure requirements for unlicensed wireless microphones capable of operating in the 600 MHz service band. Any person who manufactures, sells, leases, or offers for sale or lease, unlicensed wireless microphones that are capable of operating in the 600 MHz service band, as defi... |
ta-title="15.37(k)(1)">(1) Such persons must display the consumer disclosure text, as specified by the Consumer and Governmental Affairs Bureau, at the point of sale or lease of each such unlicensed wireless microphone. The text must be displayed in a clear, conspicuous, and readily legible manner. One way to fulfill t... |
the box), a sticker, or other means. Another way to fulfill this requirement is to display the text immediately adjacent to each unlicensed wireless microphone offered for sale or lease and clearly associated with the model to which it pertains.
(2) If such persons offer such unlicensed wireless microphones via dire... |
e proximity to the images and descriptions of each such unlicensed wireless microphone. The text should be in a size large enough to be clear, conspicuous, and readily legible, consistent with the dimensions of the advertisement or description.
(3) If such persons have Web sites pertaining to these unlicensed wirele... |
legible manner (even in the event such persons do not sell unlicensed wireless microphones directly to the public).
(4) The consumer disclosure text described in paragraph (k)(1) of this section is set forth in Figure 1 to this paragraph.
<img s |
rc="https://img.federalregister.gov/ER12MR18.004/ER12MR18.004_large.png" loading="lazy" style="height: 399px; width: 823px;">
(l) The certification of wideband vehicular radars designed to operate in the 23.12-29 GHz band under § 15.252 and ultra-wideband vehicular radars designed to operate in the 22-29 GHz band un... |
e-47/section-15.515" class="cfr external">§ 15.515 shall not be permitted on or after September 20, 2018.
(m) The manufacture, importation, marketing, sale, and installation of wideband or ultra-wideband vehicular radars that are designed to operate in the 23.12-29 GHz band under § 15.252 and/or in the 22-29 GHz ban... |
tle-47/section-15.515" class="cfr external">§ 15.515 shall not be permitted after January 1, 2022. Notwithstanding the foregoing, sale and installation of such radars is permitted, for the life of the vehicle, when the following conditions have been met:
(1) The sale and installation is for the exclusive purpose of r... |
in the 23.12-29 GHz band under § 15.252 and/or in the 22-29 GHz band under § 15.515;
(2) The equipment being repaired or replaced has been installed in the vehicle on or before January 1, 2022; and
<p class="indent-2" data-title="15.37(m) |