new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

May 7

ECGNet: A generative adversarial network (GAN) approach to the synthesis of 12-lead ECG signals from single lead inputs

Electrocardiography (ECG) signal generation has been heavily explored using generative adversarial networks (GAN) because the implementation of 12-lead ECGs is not always feasible. The GAN models have achieved remarkable results in reproducing ECG signals but are only designed for multiple lead inputs and the features the GAN model preserves have not been identified-limiting the generated signals use in cardiovascular disease (CVD)-predictive models. This paper presents ECGNet which is a procedure that generates a complete set of 12-lead ECG signals from any single lead input using a GAN framework with a bidirectional long short-term memory (LSTM) generator and a convolutional neural network (CNN) discriminator. Cross and auto-correlation analysis performed on the generated signals identifies features conserved during the signal generation-i.e., features that can characterize the unique-nature of each signal and thus likely indicators of CVD. Finally, by using ECG signals annotated with the CVD-indicative features detailed by the correlation analysis as inputs for a CVD-onset-predictive CNN model, we overcome challenges preventing the prediction of multiple-CVD targets. Our models are experimented on 15s 12-lead ECG dataset recorded using MyoVista's wavECG. Functional outcome data for each patient is recorded and used in the CVD-predictive model. Our best GAN model achieves state-of-the-art accuracy with Frechet Distance (FD) scores of 4.73, 4.89, 5.18, 4.77, 4.71, and 5.55 on the V1-V6 pre-cordial leads respectively and shows strength in preserving the P-Q segments and R-peaks in the generated signals. To the best of our knowledge, ECGNet is the first to predict all of the remaining eleven leads from the input of any single lead.

  • 3 authors
·
Sep 23, 2023

Physiology-Aware Masked Cross-Modal Reconstruction for Biosignal Representation Learning

Biosignals acquired from different locations on the body often provide temporally ordered views of the same underlying physiological process. However, most existing self supervised learning methods treat these signals as interchangeable views, overlooking the directional temporal dynamics that link them. A canonical example is the relationship between electrocardiography (ECG), which captures the electrical activation initiating each heartbeat, and photoplethysmography (PPG), which records the resulting peripheral pulse delayed by vascular dynamics. To capture this structured relationship, we introduce xMAE, a biosignal pretraining framework that leverages masked cross modal reconstruction across temporally ordered biosignals as a training time constraint to encourage physiologically meaningful timing structure in the learned representations. We show that pretraining with xMAE yields representations that outperform both unimodal and multimodal baselines on 15 of 19 downstream tasks, including cardiovascular outcome prediction, abnormal laboratory test detection, sleep staging, and demographic inference, while generalizing across devices, body locations, and acquisition settings. Further analysis suggests that the ECG PPG timing structure is reflected in the learned PPG representations. More broadly, xMAE demonstrates the effectiveness of incorporating temporal structure into multimodal pretraining when signals observe different stages of a shared underlying process. Code is available at https://github.com/hzhou3/xMAE.

  • 15 authors
·
Apr 30

Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video

Human health can be critically affected by cardiovascular diseases, such as hypertension, arrhythmias, and stroke. Heart rate and blood pressure are important biometric information for the monitoring of cardiovascular system and early diagnosis of cardiovascular diseases. Existing methods for estimating the heart rate are based on electrocardiography and photoplethyomography, which require contacting the sensor to the skin surface. Moreover, catheter and cuff-based methods for measuring blood pressure cause inconvenience and have limited applicability. Therefore, in this thesis, we propose a vision-based method for estimating the heart rate and blood pressure. This thesis proposes a 2-stage deep learning framework consisting of a dual remote photoplethysmography network (DRP-Net) and bounded blood pressure network (BBP-Net). In the first stage, DRP-Net infers remote photoplethysmography (rPPG) signals for the acral and facial regions, and these phase-shifted rPPG signals are utilized to estimate the heart rate. In the second stage, BBP-Net integrates temporal features and analyzes phase discrepancy between the acral and facial rPPG signals to estimate SBP and DBP values. To improve the accuracy of estimating the heart rate, we employed a data augmentation method based on a frame interpolation model. Moreover, we designed BBP-Net to infer blood pressure within a predefined range by incorporating a scaled sigmoid function. Our method resulted in estimating the heart rate with the mean absolute error (MAE) of 1.78 BPM, reducing the MAE by 34.31 % compared to the recent method, on the MMSE-HR dataset. The MAE for estimating the systolic blood pressure (SBP) and diastolic blood pressure (DBP) were 10.19 mmHg and 7.09 mmHg. On the V4V dataset, the MAE for the heart rate, SBP, and DBP were 3.83 BPM, 13.64 mmHg, and 9.4 mmHg, respectively.

  • 2 authors
·
Jan 9, 2024

PPGFlowECG: Latent Rectified Flow with Cross-Modal Encoding for PPG-Guided ECG Generation and Cardiovascular Disease Detection

In clinical practice, electrocardiography (ECG) remains the gold standard for cardiac monitoring, providing crucial insights for diagnosing a wide range of cardiovascular diseases (CVDs). However, its reliance on specialized equipment and trained personnel limits feasibility for continuous routine monitoring. Photoplethysmography (PPG) offers accessible, continuous monitoring but lacks definitive electrophysiological information, preventing conclusive diagnosis. Generative models present a promising approach to translate PPG into clinically valuable ECG signals, yet current methods face substantial challenges, including the misalignment of physiological semantics in generative models and the complexity of modeling in high-dimensional signals. To this end, we propose PPGFlowECG, a two-stage framework that aligns PPG and ECG in a shared latent space via the CardioAlign Encoder and employs latent rectified flow to generate ECGs with high fidelity and interpretability. To the best of our knowledge, this is the first study to experiment on MCMED, a newly released clinical-grade dataset comprising over 10 million paired PPG-ECG samples from more than 118,000 emergency department visits with expert-labeled cardiovascular disease annotations. Results demonstrate the effectiveness of our method for PPG-to-ECG translation and cardiovascular disease detection. Moreover, cardiologist-led evaluations confirm that the synthesized ECGs achieve high fidelity and improve diagnostic reliability, underscoring our method's potential for real-world cardiovascular screening.

  • 9 authors
·
Sep 24, 2025

KorMedMCQA-V: A Multimodal Benchmark for Evaluating Vision-Language Models on the Korean Medical Licensing Examination

We introduce KorMedMCQA-V, a Korean medical licensing-exam-style multimodal multiple-choice question answering benchmark for evaluating vision-language models (VLMs). The dataset consists of 1,534 questions with 2,043 associated images from Korean Medical Licensing Examinations (2012-2023), with about 30% containing multiple images requiring cross-image evidence integration. Images cover clinical modalities including X-ray, computed tomography (CT), electrocardiography (ECG), ultrasound, endoscopy, and other medical visuals. We benchmark over 50 VLMs across proprietary and open-source categories-spanning general-purpose, medical-specialized, and Korean-specialized families-under a unified zero-shot evaluation protocol. The best proprietary model (Gemini-3.0-Pro) achieves 96.9% accuracy, the best open-source model (Qwen3-VL-32B-Thinking) 83.7%, and the best Korean-specialized model (VARCO-VISION-2.0-14B) only 43.2%. We further find that reasoning-oriented model variants gain up to +20 percentage points over instruction-tuned counterparts, medical domain specialization yields inconsistent gains over strong general-purpose baselines, all models degrade on multi-image questions, and performance varies notably across imaging modalities. By complementing the text-only KorMedMCQA benchmark, KorMedMCQA-V forms a unified evaluation suite for Korean medical reasoning across text-only and multimodal conditions. The dataset is available via Hugging Face Datasets: https://huggingface.co/datasets/seongsubae/KorMedMCQA-V.

  • 4 authors
·
Feb 14

Mamba-based Deep Learning Approach for Sleep Staging on a Wireless Multimodal Wearable System without Electroencephalography

Study Objectives: We investigate a Mamba-based deep learning approach for sleep staging on signals from ANNE One (Sibel Health, Evanston, IL), a non-intrusive dual-module wireless wearable system measuring chest electrocardiography (ECG), triaxial accelerometry, and chest temperature, and finger photoplethysmography and finger temperature. Methods: We obtained wearable sensor recordings from 357 adults undergoing concurrent polysomnography (PSG) at a tertiary care sleep lab. Each PSG recording was manually scored and these annotations served as ground truth labels for training and evaluation of our models. PSG and wearable sensor data were automatically aligned using their ECG channels with manual confirmation by visual inspection. We trained a Mamba-based recurrent neural network architecture on these recordings. Ensembling of model variants with similar architectures was performed. Results: After ensembling, the model attains a 3-class (wake, non rapid eye movement [NREM] sleep, rapid eye movement [REM] sleep) balanced accuracy of 84.02%, F1 score of 84.23%, Cohen's κ of 72.89%, and a Matthews correlation coefficient (MCC) score of 73.00%; a 4-class (wake, light NREM [N1/N2], deep NREM [N3], REM) balanced accuracy of 75.30%, F1 score of 74.10%, Cohen's κ of 61.51%, and MCC score of 61.95%; a 5-class (wake, N1, N2, N3, REM) balanced accuracy of 65.11%, F1 score of 66.15%, Cohen's κ of 53.23%, MCC score of 54.38%. Conclusions: Our Mamba-based deep learning model can successfully infer major sleep stages from the ANNE One, a wearable system without electroencephalography (EEG), and can be applied to data from adults attending a tertiary care sleep clinic.

  • 12 authors
·
Nov 24, 2025

CE-SSL: Computation-Efficient Semi-Supervised Learning for ECG-based Cardiovascular Diseases Detection

The label scarcity problem is the main challenge that hinders the wide application of deep learning systems in automatic cardiovascular diseases (CVDs) detection using electrocardiography (ECG). Tuning pre-trained models alleviates this problem by transferring knowledge learned from large datasets to downstream small datasets. However, bottlenecks in computational efficiency and detection performance limit its clinical applications. It is difficult to improve the detection performance without significantly sacrificing the computational efficiency during model training. Here, we propose a computation-efficient semi-supervised learning paradigm (CE-SSL) for robust and computation-efficient CVDs detection using ECG. It enables a robust adaptation of pre-trained models on downstream datasets with limited supervision and high computational efficiency. First, a random-deactivation technique is developed to achieve robust and fast low-rank adaptation of pre-trained weights. Subsequently, we propose a one-shot rank allocation module to determine the optimal ranks for the update matrices of the pre-trained weights. Finally, a lightweight semi-supervised learning pipeline is introduced to enhance model performance by leveraging labeled and unlabeled data with high computational efficiency. Extensive experiments on four downstream datasets demonstrate that CE-SSL not only outperforms the state-of-the-art methods in multi-label CVDs detection but also consumes fewer GPU footprints, training time, and parameter storage space. As such, this paradigm provides an effective solution for achieving high computational efficiency and robust detection performance in the clinical applications of pre-trained models under limited supervision. Code and Supplementary Materials are available at https://github.com/KAZABANA/CE-SSL

  • 7 authors
·
Jun 20, 2024