File size: 18,127 Bytes
881f9f2
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
"""
Generate synthetic Smart Grid transformer data for development/testing.

This produces the same CSV schemas that the real Kaggle datasets will be
processed into.  Real data replaces these once the pipeline runs against
the downloaded Kaggle files.

Run:
    python3 data/generate_synthetic.py

Outputs (all in data/processed/):
    asset_metadata.csv    — 20 transformers, static attributes
    sensor_readings.csv   — hourly readings for 30 days per transformer
    failure_modes.csv     — catalogue of DGA-based fault types
    dga_records.csv       — one DGA sample per transformer (some faulty)
    rul_labels.csv        — daily RUL estimates per transformer
    fault_records.csv     — maintenance / work-order history

Synthetic transformer_id key: T-001 … T-020
  T-001 to T-010  →  healthy / approaching end-of-life
  T-011 to T-015  →  minor faults (partial discharge, thermal < 300°C)
  T-016 to T-020  →  serious faults (arcing, thermal > 700°C)
"""

from __future__ import annotations

import random
from datetime import datetime, timedelta
from pathlib import Path

import numpy as np
import pandas as pd

try:
    from data.constants import HI_FULL_HEALTH_DAYS
except ModuleNotFoundError:
    from constants import HI_FULL_HEALTH_DAYS

SEED = 42
rng = np.random.default_rng(SEED)
random.seed(SEED)

OUT = Path(__file__).parent / "processed"
OUT.mkdir(parents=True, exist_ok=True)

N_TRANSFORMERS = 20
IDS = [f"T-{i:03d}" for i in range(1, N_TRANSFORMERS + 1)]

START = datetime(2024, 1, 1)
END = datetime(2024, 1, 31)
PROFILE_TO_FDD_CATEGORY = {"healthy": 1, "degraded": 2, "critical": 4}
# Category 3 only appears in the Kaggle-backed build_processed path.
PROFILE_TO_RUL_BASE = {"healthy": 3650, "degraded": 730, "critical": 90}


# ---------------------------------------------------------------------------
# 1. asset_metadata.csv
# ---------------------------------------------------------------------------
# Why: IoT server needs static attributes to answer "what is transformer T-007?"
# Columns mirror what AssetOpsBench IoT tools return for other domains.


def make_asset_metadata() -> pd.DataFrame:
    manufacturers = ["ABB", "Siemens", "GE", "Eaton", "Schneider Electric"]
    locations = [
        "Substation Alpha",
        "Substation Beta",
        "Substation Gamma",
        "Distribution Center 1",
        "Distribution Center 2",
        "Industrial Park A",
        "Industrial Park B",
    ]
    voltage_classes = ["11kV/0.4kV", "33kV/11kV", "132kV/33kV"]
    ratings_kva = [500, 1000, 1500, 2000, 2500, 5000]

    rows = []
    for i, tid in enumerate(IDS):
        profile_key = "healthy" if i < 10 else ("degraded" if i < 15 else "critical")
        install_year = rng.integers(2005, 2020)
        rows.append(
            {
                "transformer_id": tid,
                "name": f"Power Transformer {tid}",
                "manufacturer": random.choice(manufacturers),
                "location": random.choice(locations),
                "voltage_class": random.choice(voltage_classes),
                "rating_kva": random.choice(ratings_kva),
                "install_date": f"{install_year}-{rng.integers(1,13):02d}-{rng.integers(1,28):02d}",
                "age_years": 2024 - install_year,
                # health_status: healthy (0), degraded (1), critical (2)
                "health_status": 0 if i < 10 else (1 if i < 15 else 2),
                "fdd_category": PROFILE_TO_FDD_CATEGORY[profile_key],
                "rul_days": int(
                    max(
                        30,
                        rng.normal(
                            PROFILE_TO_RUL_BASE[profile_key],
                            PROFILE_TO_RUL_BASE[profile_key] * 0.12,
                        ),
                    )
                ),
                "in_service": True,
            }
        )

    df = pd.DataFrame(rows)
    path = OUT / "asset_metadata.csv"
    df.to_csv(path, index=False)
    print(f"  wrote {path}  ({len(df)} rows)")
    return df


# ---------------------------------------------------------------------------
# 2. sensor_readings.csv
# ---------------------------------------------------------------------------
# Why: IoT server's get_sensor_readings() returns this.
# Sensors: winding_temp, oil_temp, load_current, voltage_hv, voltage_lv.
# Faulty transformers have elevated temperature / voltage anomalies.

SENSORS = {
    "winding_temp_top_c": {
        "healthy": (50, 10),
        "degraded": (80, 15),
        "critical": (105, 20),
        "unit": "°C",
    },
    "oil_temp_c": {
        "healthy": (45, 8),
        "degraded": (70, 12),
        "critical": (90, 18),
        "unit": "°C",
    },
    "load_current_a": {
        "healthy": (200, 40),
        "degraded": (220, 45),
        "critical": (240, 50),
        "unit": "A",
    },
    "voltage_hv_kv": {
        "healthy": (33, 0.5),
        "degraded": (33, 1.0),
        "critical": (32, 2.0),
        "unit": "kV",
    },
    "voltage_lv_kv": {
        "healthy": (11, 0.2),
        "degraded": (11, 0.4),
        "critical": (10.5, 1.0),
        "unit": "kV",
    },
    "power_factor": {
        "healthy": (0.95, 0.02),
        "degraded": (0.90, 0.04),
        "critical": (0.82, 0.06),
        "unit": "",
    },
}


def make_sensor_readings(metadata: pd.DataFrame) -> pd.DataFrame:
    hours = int((END - START).total_seconds() / 3600)
    timestamps = [START + timedelta(hours=h) for h in range(hours)]

    rows = []
    status_map = dict(zip(metadata["transformer_id"], metadata["health_status"]))

    for tid in IDS:
        status_key = ["healthy", "degraded", "critical"][status_map[tid]]
        for sensor_id, params in SENSORS.items():
            mu, sigma = params[status_key]
            values = rng.normal(mu, sigma, len(timestamps))
            # Inject a spike anomaly into critical transformers
            if status_map[tid] == 2 and "temp" in sensor_id:
                spike_idx = rng.integers(100, len(timestamps) - 50)
                values[spike_idx : spike_idx + 12] += rng.uniform(15, 30)
            for ts, val in zip(timestamps, values):
                rows.append(
                    {
                        "transformer_id": tid,
                        "timestamp": ts.isoformat(),
                        "sensor_id": sensor_id,
                        "value": round(float(val), 3),
                        "unit": params["unit"],
                        "source": "synthetic",
                    }
                )

    df = pd.DataFrame(rows)
    path = OUT / "sensor_readings.csv"
    df.to_csv(path, index=False)
    print(f"  wrote {path}  ({len(df):,} rows)")
    return df


# ---------------------------------------------------------------------------
# 3. failure_modes.csv
# ---------------------------------------------------------------------------
# Why: FMSR server's search_failure_modes() and get_sensor_correlation()
#      return entries from this table.
# Based on IEC 60599 DGA interpretation standard and Duval triangle method.


def make_failure_modes() -> pd.DataFrame:
    rows = [
        {
            "failure_mode_id": "FM-001",
            "name": "Partial Discharge",
            "dga_label": "Partial discharge",
            "description": "Low-energy electrical discharge within insulation voids. "
            "Indicated by elevated H2 and CH4 with trace C2H2.",
            "severity": "low",
            "iec_code": "PD",
            "key_gases": "H2,CH4",
            "recommended_action": "Monitor closely; schedule inspection within 90 days",
        },
        {
            "failure_mode_id": "FM-002",
            "name": "Low-Temperature Overheating (< 300°C)",
            "dga_label": "Low-temperature overheating",
            "description": "Low-temperature thermal fault, typically in core laminations "
            "or due to overload. Elevated CH4 and C2H4.",
            "severity": "medium",
            "iec_code": "T1",
            "key_gases": "CH4,C2H4",
            "recommended_action": "Reduce load; inspect within 30 days",
        },
        {
            "failure_mode_id": "FM-003",
            "name": "Thermal Fault 300-700°C",
            "dga_label": "Middle-temperature overheating",
            "description": "Medium-temperature thermal fault in conductors or connections. "
            "High C2H4 relative to C2H6.",
            "severity": "high",
            "iec_code": "T2",
            "key_gases": "C2H4,C2H6",
            "recommended_action": "De-energize and inspect within 48 hours",
        },
        {
            "failure_mode_id": "FM-004",
            "name": "High-Temperature Overheating (> 700°C)",
            "dga_label": "High-temperature overheating",
            "description": "Severe winding conductor overheating. "
            "Very high C2H4 and C2H6.",
            "severity": "critical",
            "iec_code": "T3",
            "key_gases": "C2H4,C2H6,H2",
            "recommended_action": "Immediate de-energization required",
        },
        {
            "failure_mode_id": "FM-005",
            "name": "Spark Discharge",
            "dga_label": "Spark discharge",
            "description": "Low-energy electrical sparking in oil. "
            "Elevated C2H2 and H2.",
            "severity": "high",
            "iec_code": "D1",
            "key_gases": "C2H2,H2",
            "recommended_action": "De-energize and inspect within 48 hours",
        },
        {
            "failure_mode_id": "FM-006",
            "name": "Arc Discharge",
            "dga_label": "Arc discharge",
            "description": "High-energy arcing causing severe oil decomposition. "
            "Very high C2H2 and H2.",
            "severity": "critical",
            "iec_code": "D2",
            "key_gases": "C2H2,H2,C2H4",
            "recommended_action": "Immediate de-energization and emergency inspection",
        },
    ]

    df = pd.DataFrame(rows)
    path = OUT / "failure_modes.csv"
    df.to_csv(path, index=False)
    print(f"  wrote {path}  ({len(df)} rows)")
    return df


# ---------------------------------------------------------------------------
# 4. dga_records.csv
# ---------------------------------------------------------------------------
# Why: FMSR server's analyze_dga() interprets these gas concentrations.
# Gas values in ppm (parts per million), typical IEC 60599 ranges.
# Each transformer gets one DGA sample; fault profile matches health_status.

DGA_PROFILES = {
    # (h2, ch4, c2h2, c2h4, c2h6, co, co2) mean ± sigma
    "healthy": [(10, 3), (5, 2), (0.1, 0.05), (2, 1), (2, 0.8), (200, 40), (1500, 200)],
    "degraded": [(50, 15), (30, 10), (2, 1), (25, 8), (10, 3), (300, 60), (2000, 300)],
    "critical": [
        (200, 50),
        (80, 20),
        (20, 8),
        (100, 25),
        (40, 10),
        (500, 80),
        (3500, 400),
    ],
}
DGA_COLS = [
    "dissolved_h2_ppm",
    "dissolved_ch4_ppm",
    "dissolved_c2h2_ppm",
    "dissolved_c2h4_ppm",
    "dissolved_c2h6_ppm",
    "dissolved_co_ppm",
    "dissolved_co2_ppm",
]

FAULT_LABEL_MAP = {
    "healthy": "Normal",
    "degraded": "Low-temperature overheating",
    "critical": "Arc discharge",
}


def make_dga_records(metadata: pd.DataFrame) -> pd.DataFrame:
    status_map = dict(zip(metadata["transformer_id"], metadata["health_status"]))
    rows = []
    for tid in IDS:
        profile_key = ["healthy", "degraded", "critical"][status_map[tid]]
        profile = DGA_PROFILES[profile_key]
        gas_vals = {
            col: round(max(0.0, float(rng.normal(mu, sigma))), 2)
            for col, (mu, sigma) in zip(DGA_COLS, profile)
        }
        rows.append(
            {
                "transformer_id": tid,
                "sample_date": (
                    START + timedelta(days=int(rng.integers(0, 30)))
                ).strftime("%Y-%m-%d"),
                **gas_vals,
                "fault_label": FAULT_LABEL_MAP[profile_key],
                "source_dataset": "synthetic",
            }
        )

    df = pd.DataFrame(rows)
    path = OUT / "dga_records.csv"
    df.to_csv(path, index=False)
    print(f"  wrote {path}  ({len(df)} rows)")
    return df


# ---------------------------------------------------------------------------
# 5. rul_labels.csv
# ---------------------------------------------------------------------------
# Why: TSFM server's forecast_rul() returns predictions against these labels.
# RUL decreases each day; critical transformers have low starting RUL.

RUL_START = {
    "healthy": (3650, 500),  # ~10 years remaining
    "degraded": (730, 200),  # ~2 years
    "critical": (90, 30),  # ~3 months
}


def make_rul_labels(metadata: pd.DataFrame) -> pd.DataFrame:
    status_map = dict(zip(metadata["transformer_id"], metadata["health_status"]))
    rows = []
    for tid in IDS:
        profile_key = ["healthy", "degraded", "critical"][status_map[tid]]
        mu, sigma = RUL_START[profile_key]
        base_rul = max(10, int(rng.normal(mu, sigma)))
        # ~1 RUL-day consumed per calendar day, with small transformer-to-transformer variation.
        daily_deg = float(rng.uniform(0.9, 1.1))
        days = (END - START).days
        for d in range(days + 1):
            day = START + timedelta(days=d)
            rul = max(0, base_rul - int(round(d * daily_deg)))
            health_index = min(1.0, max(0.0, rul / HI_FULL_HEALTH_DAYS))
            rows.append(
                {
                    "transformer_id": tid,
                    "timestamp": day.strftime("%Y-%m-%d"),
                    "rul_days": rul,
                    "health_index": round(float(health_index), 4),
                    "fdd_category": PROFILE_TO_FDD_CATEGORY[profile_key],
                }
            )

    df = pd.DataFrame(rows)
    path = OUT / "rul_labels.csv"
    df.to_csv(path, index=False)
    print(f"  wrote {path}  ({len(df)} rows)")
    return df


def sync_asset_metadata_rul_days(
    metadata: pd.DataFrame, rul_labels: pd.DataFrame
) -> pd.DataFrame:
    """Align asset_metadata.rul_days to the latest RUL label for each transformer."""
    latest_rul = (
        rul_labels.sort_values("timestamp")
        .groupby("transformer_id", sort=False)
        .last()["rul_days"]
        .astype(int)
    )
    synced = metadata.copy()
    synced["rul_days"] = (
        synced["transformer_id"].map(latest_rul).fillna(synced["rul_days"]).astype(int)
    )
    path = OUT / "asset_metadata.csv"
    synced.to_csv(path, index=False)
    print(f"  rewrote {path} with latest RUL labels")
    return synced


# ---------------------------------------------------------------------------
# 6. fault_records.csv
# ---------------------------------------------------------------------------
# Why: WO server's list_work_orders() and create_work_order() reference these.
# Each critical/degraded transformer has at least one historical fault event.

FAULT_TYPES = [
    "Transformer Failure",
    "Line Breakage",
    "Overload Trip",
    "Cooling System Failure",
    "Tap Changer Malfunction",
    "Insulation Degradation",
]
MAINTENANCE_STATUSES = ["Scheduled", "Pending", "Completed"]
WEATHER_CONDITIONS = ["Clear", "Rainy", "Windy", "Stormy"]
COMPONENT_HEALTH = {0: "Normal", 1: "Warning", 2: "Faulty"}
DOWNTIME_BY_HEALTH = {
    0: (2, 6),
    1: (8, 24),
    2: (24, 72),
}


def make_fault_records(metadata: pd.DataFrame) -> pd.DataFrame:
    status_map = dict(zip(metadata["transformer_id"], metadata["health_status"]))
    rows = []
    fault_counter = 1

    for tid in IDS:
        health = status_map[tid]
        # Healthy: 0-1 records, degraded: 1-3, critical: 2-5
        n_faults = {
            0: rng.integers(0, 2),
            1: rng.integers(1, 4),
            2: rng.integers(2, 6),
        }[health]
        for _ in range(n_faults):
            min_downtime, max_downtime = DOWNTIME_BY_HEALTH[health]
            downtime = int(rng.integers(min_downtime, max_downtime + 1))
            rows.append(
                {
                    "transformer_id": tid,
                    "fault_id": f"F{fault_counter:03d}",
                    "fault_type": random.choice(FAULT_TYPES),
                    "location": f"Substation {random.choice(['Alpha', 'Beta', 'Gamma', 'Delta'])}",
                    "voltage_v": int(rng.choice([11000, 33000, 132000])),
                    "current_a": int(max(0, rng.normal(220, 40))),
                    "power_load_mw": round(max(0.0, float(rng.normal(45, 8))), 2),
                    "temperature_c": round(float(rng.normal(28 + health * 8, 4)), 1),
                    "wind_speed_kmh": round(max(0.0, float(rng.normal(15, 6))), 1),
                    "weather_condition": random.choice(WEATHER_CONDITIONS),
                    "maintenance_status": random.choice(MAINTENANCE_STATUSES),
                    "component_health": COMPONENT_HEALTH[health],
                    "duration_hrs": round(
                        float(max(0.5, rng.normal(2 + health * 3, 1.2))), 1
                    ),
                    "downtime_hrs": max(1, downtime + int(rng.integers(-2, 4))),
                }
            )
            fault_counter += 1

    df = (
        pd.DataFrame(rows)
        .sort_values(["transformer_id", "fault_id"])
        .reset_index(drop=True)
    )
    path = OUT / "fault_records.csv"
    df.to_csv(path, index=False)
    print(f"  wrote {path}  ({len(df)} rows)")
    return df


# ---------------------------------------------------------------------------
# Main
# ---------------------------------------------------------------------------

if __name__ == "__main__":
    print(f"Generating synthetic Smart Grid data → {OUT}\n")
    meta = make_asset_metadata()
    make_sensor_readings(meta)
    make_failure_modes()
    make_dga_records(meta)
    rul = make_rul_labels(meta)
    meta = sync_asset_metadata_rul_days(meta, rul)
    make_fault_records(meta)
    print("\nDone. All files written to data/processed/")
    print(
        "These are SYNTHETIC — replace with real Kaggle data once API access is granted."
    )