| # UnitCommitment.jl: Optimization Package for Security-Constrained Unit Commitment |
| # Copyright (C) 2020, UChicago Argonne, LLC. All rights reserved. |
| # Released under the modified BSD license. See COPYING.md for more details. |
|
|
| """ |
| slice(instance, range) |
|
|
| Creates a new instance, with only a subset of the time periods. |
| This function does not modify the provided instance. The initial |
| conditions are also not modified. |
|
|
| Example |
| ------- |
|
|
| ```julia |
| # Build a 2-hour UC instance |
| instance = UnitCommitment.read_benchmark("matpower/case118/2017-02-01") |
| modified = UnitCommitment.slice(instance, 1:2) |
| ``` |
| """ |
| function slice( |
| instance::UnitCommitmentInstance, |
| range::UnitRange{Int}, |
| )::UnitCommitmentInstance |
| modified = deepcopy(instance) |
| modified.time = length(range) |
| for sc in modified.scenarios |
| sc.power_balance_penalty = sc.power_balance_penalty[range] |
| for r in sc.reserves |
| r.amount = r.amount[range] |
| end |
| for u in sc.thermal_units |
| u.max_power = u.max_power[range] |
| u.min_power = u.min_power[range] |
| u.must_run = u.must_run[range] |
| u.min_power_cost = u.min_power_cost[range] |
| for s in u.cost_segments |
| s.mw = s.mw[range] |
| s.cost = s.cost[range] |
| end |
| end |
| for pu in sc.profiled_units |
| pu.max_power = pu.max_power[range] |
| pu.min_power = pu.min_power[range] |
| pu.cost = pu.cost[range] |
| end |
| for b in sc.buses |
| b.load = b.load[range] |
| end |
| for l in sc.lines |
| l.normal_flow_limit = l.normal_flow_limit[range] |
| l.emergency_flow_limit = l.emergency_flow_limit[range] |
| l.flow_limit_penalty = l.flow_limit_penalty[range] |
| end |
| for ps in sc.price_sensitive_loads |
| ps.demand = ps.demand[range] |
| ps.revenue = ps.revenue[range] |
| end |
| for su in sc.storage_units |
| su.min_level = su.min_level[range] |
| su.max_level = su.max_level[range] |
| su.simultaneous_charge_and_discharge = |
| su.simultaneous_charge_and_discharge[range] |
| su.charge_cost = su.charge_cost[range] |
| su.discharge_cost = su.discharge_cost[range] |
| su.charge_efficiency = su.charge_efficiency[range] |
| su.discharge_efficiency = su.discharge_efficiency[range] |
| su.loss_factor = su.loss_factor[range] |
| su.min_charge_rate = su.min_charge_rate[range] |
| su.max_charge_rate = su.max_charge_rate[range] |
| su.min_discharge_rate = su.min_discharge_rate[range] |
| su.max_discharge_rate = su.max_discharge_rate[range] |
| end |
| end |
| return modified |
| end |
|
|